A Cat A office fit out is the basic, functional finish usually delivered by a landlord before a tenant installs their its own workplace. It commonly includes general floor and ceiling systems, basic lighting, mechanical and electrical distribution, fire and life-safety infrastructure and decorated core or perimeter surfaces. It does not normally include the occupier's final room layout, furniture, branding, IT, audio-visual systems or bespoke finishes.
Cat A is a property-market convention, not one universal statutory specification. The lease, agreement for lease and landlord works schedule define what is actually included. Two spaces marketed as Cat A can have different ceilings, floor finishes, lighting, washrooms, services and controls.
RICS describes Cat A as a functional space with basic finishes and no occupier-specific partitions, meeting rooms or offices. Cat B follows and delivers the tenant's bespoke workplace. Understanding the boundary early prevents duplicated costs and abortive work.
Mowbray can assess the existing or proposed Cat A condition and develop the Cat B office design and construction needed for occupation.
Cat A is a property-market convention, not one universal statutory specification. The lease, agreement for lease and landlord works schedule define what is actually included. Two spaces marketed as Cat A can have different ceilings, floor finishes, lighting, washrooms, services and controls.
RICS describes Cat A as a functional space with basic finishes and no occupier-specific partitions, meeting rooms or offices. Cat B follows and delivers the tenant's bespoke workplace. Understanding the boundary early prevents duplicated costs and abortive work.
Mowbray can assess the existing or proposed Cat A condition and develop the Cat B office design and construction needed for occupation.
Ceilings and soffits
Traditional Cat A offices often have suspended ceiling grids and tiles. Contemporary spaces may have an exposed soffit that is cleaned, repaired and decorated, with visible services arranged above the occupied zone. The ceiling approach affects acoustics, lighting, fire detection, ventilation and access for maintenance. A Cat B design containing acoustic rafts, feature lighting or full-height partitions needs coordination with the base condition. A suspended ceiling should be inspected for condition and suitability rather than assumed to be reusable. Tile staining, damaged grids or poor coordination with services may require work even where the lease calls the floor Cat A.Lighting and electrical services
Cat A lighting normally provides a general level for an open, generic floor. The grid may not align with the tenant's desks, meeting rooms or screens. Cat B works can require fittings to be moved, added, removed or controlled differently. Electrical distribution may reach the floor or tenant board without providing final desk power and specialist circuits. Confirm spare capacity, metering, containment, small-power assumptions and resilience requirements. A technology-led business may need more power, cooling and data capacity than the base design anticipated. These requirements should be tested before the lease and layout are finalised.
Heating, cooling and ventilation
The landlord may provide central systems, terminal units, ductwork or capped connections. Capacity and zoning are more important than the presence of equipment. A system designed for an open floor may not serve multiple enclosed rooms without modification. Meeting rooms, kitchens, server areas and densely occupied zones can have higher heat and fresh-air demands. The Cat B designer needs plant information, controls strategy, commissioning data and any landlord restrictions. For more detail, see What Is an Office Fit Out. If the tenant layout is known early, Cat A and Cat B services can be coordinated to avoid moving recently installed diffusers, lights and controls.Fire and life-safety provisions
Cat A may include fire detection, alarms, emergency lighting, sprinklers and exit signs in a generic arrangement. Partitions and room layouts can change device positions, escape routes, compartmentation and sprinkler coverage. The final workplace still needs to meet the applicable Building Regulations and fire-safety duties. A completed landlord system does not remove the need to review and commission changes created by the tenant fit out. Fire doors, penetrations and fire stopping should be documented. Cat B contractors need accurate information before altering ceilings, walls or services.
What Cat A normally excludes
Cat A usually excludes internal offices and meeting rooms, feature finishes, tenant kitchens, loose furniture, workstations, lockers, branding, signs, data cabling, wireless systems, AV, access control and operational equipment. It may also exclude upgrades needed for the tenant's density or specialist use. A laboratory-style area, studio, high-occupancy training room or server suite can require additional structure, ventilation, power or fire measures beyond the generic provision. The tenant should avoid assuming that anything visible belongs to the landlord or will remain. The lease inventory and handover documents determine ownership and obligations.Cat A compared with shell and core
Shell and core normally provides the building structure, facade, central cores, lifts and main infrastructure while leaving the tenant area largely unfinished. Cat A brings the demise to a basic usable condition with finishes and distributed services. A shell-and-core tenant fit out can therefore include work that would otherwise sit within Cat A, such as floor systems, ceilings, lighting and service distribution. It may provide greater design freedom, but it requires more capital, design coordination and programme. The boundary varies by development. A detailed responsibility matrix is more reliable than the category name.
What is Cat A+?
Cat A+ is a landlord-fitted space intended to be more occupiable than traditional Cat A. It may contain meeting rooms, a tea point, flooring, furniture and a flexible working layout. It is marketed to tenants seeking a quicker move with lower initial fit-out commitment. There is no standard Cat A+ package. One space may be close to a full Cat B fit out, while another provides only basic rooms and furniture. Tenants should assess whether the layout, brand, technology and quality suit their operation and what alterations are permitted. A Cat A+ offer can reduce programme and waste when it genuinely meets the need. It can also create hidden cost if much of it is removed to deliver a different workplace.Cat A compared with Cat B
Cat A is generic and property-led. Cat B is occupier-specific and operational. Cat B creates the rooms, settings, finishes, furniture and technology that allow the business to work from the space. The division is not purely visual. Cat B may modify Cat A mechanical, electrical and fire systems to match the final layout. It can include structural support for operable walls, specialist acoustics, catering equipment and security. The separate Mowbray comparison page provides a detailed table of responsibilities, cost and programme implications.
Due diligence before accepting a Cat A space
A technical review should compare the landlord's information with the tenant brief. Check floor area, column grid, floor-to-ceiling height, daylight, acoustic conditions, accessibility, loading and delivery access as well as visible finishes. Services surveys and records should confirm installed capacity and condition. If information is incomplete, build investigation and risk allowances into the programme and cost plan. For budgeting context, see Office Fit-Out Cost. Landlord consent procedures also matter. The licence for alterations may require detailed drawings, insurance, contractor approvals, working hours and reinstatement security. These timescales should be included before a move date is committed.Avoiding abortive work between Cat A and Cat B
Abortive work occurs when a newly installed element is removed or substantially altered during the next stage. Common examples include ceiling tiles discarded for an exposed design, lights moved from a generic grid and mechanical terminals relocated around meeting rooms. Early coordination between landlord and tenant teams can reduce this waste. If the tenant is known before Cat A completion, the parties may agree to omit, relocate or select elements that support the Cat B design. RICS notes that clear understanding between shell, Cat A and Cat B scopes reduces abortive work and associated carbon. The commercial agreement should reflect any change in responsibility or contribution.
Building Regulations, CDM and other requirements
Relevant office works may require Building Regulations approval. Planning permission is separate and may be needed for external changes, use or listed-building considerations. Landlord consent is contractual and does not replace statutory approval. Commercial clients have duties under CDM 2015 to make suitable management arrangements and provide pre-construction information. Fire safety, asbestos, accessibility and workplace requirements need to be addressed in the final scheme. The Cat A handover should include drawings, test records, certificates, manuals and information needed by the tenant design team. Missing records can lead to repeated surveys and conservative assumptions.
Planning Cat B works from a Cat A base with Mowbray
Mowbray can survey the Cat A space, test it against the client's occupancy and room requirements, and define the tenant work needed. The proposal can identify retained elements, required modifications, furniture, finishes and approval responsibilities.A measured survey and stock analysis provide a more reliable answer than a generic capacity percentage. To discuss a layout, call Mowbray on 01572 827206, contact the Northern Office on 0113 403 1160 or email info@mowbrayltd.co.uk.

FAQs
- Is a Cat A office ready to occupy?
It is functional as a generic property space but is not normally ready for a specific business to operate. It usually lacks tenant rooms, furniture, data, AV, branding and final workplace settings.
- Does Cat A include carpet?
Sometimes, but not always. A landlord may provide raised access floor panels, a basic finish or final carpet. The written specification and lease determine the answer.
- Does Cat A include air conditioning?
It may include heating, cooling and ventilation distribution, but capacity, zoning and controls vary. The tenant should confirm whether the system supports the proposed layout and occupancy.
- Who pays for Cat A works?
The landlord commonly funds Cat A as part of preparing the property, while the tenant funds Cat B. Commercial agreements, contributions and shell-and-core lettings can change this division.
- Can a tenant change the Cat A installation?
Changes may be permitted through the landlord's licence for alterations and relevant approvals. The tenant must also consider warranty, service capacity, fire strategy and reinstatement obligations.
- Can Mowbray assess a Cat A+ office?
Yes. The existing layout and systems can be reviewed against the tenant brief to identify what can be retained, what needs adjustment and whether the apparent time or cost saving is realistic.